Ready-to-use liquid for disinfection of rotating prevision instruments. Effective against bacteria, fungi, yeasts and viruses.

  1. Home
  2. Our Offerings
  3. Sekudrill™

Contact Us

Give Us a Call

Sales Team

Wojciech Sobczyk, Country Manager Healthcare Poland:  +48 501 38 26 21

Krzysztof Bas, District Manager Poland West:  tel. 501 332 885

Mariusz Szymański, District Manager Poland East: tel. 502 442 757

Artur Idec, District Manager Poland South: tel. 501 33 94 58

Marketing Team

Agnieszka Apanasewicz, Marketing Segment Manager Healthcare (Hand and Skin): tel. 691 11 30 49

Anna Ceglarz, Marketing Segment Manager Healthcare (Environment): tel. 501 52 66 27

Katarzyna Mastek, Marketing Segment Manager Healthcare (Instruments): tel. 885 55 28 04

Anna Rozumek, Sales Support Healthcare Poland: tel. 48 12 2616 163

Thank you for your inquiry. This form is for North American inquiries only. An Ecolab Representative will be in contact with you soon.
I am interested in the following information

Product Details

Specially for precision rotary instruments.

  • Comprehensive efficacy spectrum
  • Good material compatibility
  • Ready for use liquid
Our performance Your advantage
Effective against bacteria, fungi, yeasts and viruses Safety in handling infection risks
Ready for use Ease of handling

Powerful composition of agent

Short contact times, practical, economical liquid for rotating instruments
Material-compatible formulation components Cleans and disinfects all instruments made of steel and steel alloys

Application areas

To disinfect medical instruments, especially rotating precision instruments such as tool steel, carbide and diamond cutting instruments. Can be used in burr sterilizer or ultrasonic bath For instruments that are not resistant to highly alkaline media, such as elastic polisher, ceramic abrasive wheels and root canal instruments, we recommend our products Sekusept™ Extra N or Sekusept™ PLUS.


Place instruments in the undiluted Sekudrill™ liquid immediately after use. Ensure complete wetting. Clean the instruments thoroughly using mechanism to brush or wipe. After the stated contact time, remove the instruments from the liquid and rinse with water of at least drinking quality and dry them immediately with a single use absorbent cloth. Brush off any still visible contamination and place the instruments in again.

Please also follow the reprocessing recommendations of the instrument manufacturer.

For hygienic reasons, change the liquid every day. Do not place aluminum parts in Sekudrill™.

100g contains as agents:
50g Propylene glycol, 5g potassium hydroxide.


Use (after commencement) Shelf life
In container
until the printed expiration date
As a prepared application solution2
up to 14 days

Please note the following to ensure the correct storage of environmental hygiene and instrument disinfectants: The original containers (canisters, buckets or bottles) with the disinfectant concentrate (or powder) should be stored at temperatures below 25°C and kept dry and clean. A brief period below or above the given storage temperature (e.g. during transport) will not diminish the effectiveness.
The containers are to be sealed tightly after each use. Please also take care that the concentrate remaining in the container is not contaminated when preparing the application solution.

Assuming that the application solution that is produced is not contaminated by organic material, it is to be stored in a clean, closed container or a covered instrument basin.
Please take note of the corresponding marking on the containers in which the disinfectant solutions are kept, e.g. contents, concentration, date, shelf life and batch number. Used and organically contaminated solutions are to be changed at least once per workday as per RKI recommendation.


pikto_instrumente_manuellDisinfectant for medical devices




For more product details, pack sizes and all relevant order codes, please download the product brochure below.


Ecolab Healthcare can partner with you to help increase efficiency, improve outcomes and reduce the risk of Healthcare Associated Infections (HAIs).